The Customized Digital Workflow that Adapts to your Business
Submit your impressions (digital or physical*) and DICOM files on the guide ordering platform, and our experts will propose an implant planning. After validation, LYRA ETK will take care of the 3D printing. *A courier can be sent to collect the impression.
Stage 1
I submit my impression and my cone bean on the LYRA ETK guide ordering platform.
Stage 2
LYRA ETK carries out the implant planning.
Stage 3
LYRA ETK will print the guide once I have validated it.
Stage 4
I perform the surgery.
Submit your STL file on the guide ordering platform, and LYRA ETK will take care of 3D printing the guide.
Stage 1
I do the planning myself. LYRA ETK implants are available in most planning software.
Stage 2
I place my guide on the LYRA ETK guide ordering platform.
Stage 3
LYRA ETK prints the guide.
Stage 4
I perform the surgery.
DENTAL APP
Our Services
Choose Your Guidance
Submit your impressions (digital or physical*) and DICOM files on the guide ordering platform, and our experts will propose an implant planning. After validation, LYRA ETK will take care of the 3D printing. *A courier can be sent to collect the impression.
Stage 1
I submit my impression and my cone bean on the LYRA ETK guide ordering platform.
Stage 2
LYRA ETK carries out the implant planning.
Stage 3
LYRA ETK will print the guide once I have validated it.
Stage 4
I perform the surgery.
The advantage of simplified guided surgery is that you benefit from the advantages of the guided surgery technique while using a surgical guide that can be used with any dental implant system and without a complete guided surgery kit. Only the first pass of the drill is guided. As the drilling axis is defined initially, it will be maintained throughout the surgery until the implant is inserted.
The complete guided surgery kit
To carry out your most complex clinical cases.
The kit for simplified guided surgery
To carry out your clinical cases with any implant system.
NEW: THE REDUCED-SIZE SOCKET
The complete guided surgery sleeve (reference CGC_TG) has two additional flats to position the implants as close as possible during your surgery.
This evolution allows a gain of 1mm.
FOR MORE PRECISION
- Raised hand
- Simplified Guided Surgery
- Complete Guided Surgery
- The results of the analysis showed that complete guided surgery was the most accurate, with an average deviation of 0.97 mm. Simplified guided surgery had a mean deviation of 1.43 mm. Finally, freehand surgery had a mean deviation of 2.11 mm.